FIF Frame Ionite Filter
Frame ionite filters (FIF) are designed for air purification from NH3, HF, HCl, SO2, CrO3, organic acids and amines; acid, alkali, toxic salt aerosols (NiCl2, Ni2SO4, CdSO4).
FIF filters are characterized by:
- high purification efficiency (90-95%);
- total automation of purification process;
- low power consumption;
- reliability of operation and maintenance ease;
- purification efficiency practically doesn’t depend on fluctuations of pollution agent concentrations and air-flow speed.
Air purification is carried out during the filtration of the air through MION® ion-exchange filtermedia which functional groups bind toxic components. FIF filter specification.
|
FIF-0,5 |
FIF -5 |
FIF -10 |
FIF -20 |
Productivity, m3/hour |
500 |
5 000 |
10 000 |
20 000 |
Filtration area, m2 |
3.0 |
22 |
42 |
108 |
Aerodynamic resistance, no more than, Pa:
-
periodic regeneration mode
-
continuous regeneration mode
|
300
500 |
300
500 |
350
600 |
400
700 |
Regeneration duration, no more than, hour |
1 |
1,5 |
2 |
2 |
Filtration linear speed, m/sec |
0,046 |
0,06 |
0,07 |
0,05 |
?, mm |
865 |
968 |
940 |
1694 |
?, mm |
1200 |
1825 |
2482 |
2476 |
?, mm |
875 |
1655 |
1950 |
2250 |
D, mm |
550 |
810 |
815 |
1560 |
E, mm |
585 |
1360 |
1664 |
1965 |
F, mm |
- |
1318 |
1832 |
1827 |
G, mm |
- |
570 |
745 |
743 |
H, mm |
850 |
1226 |
1638 |
1626 |
JxK, mm |
415?427 |
1196?905 |
1500 x1397 |
1800 ?1401 |
Dry filter mass as a unit, no more than, kg |
125 |
525 |
735 |
1325 |
Tank volume, m3 |
0.12 |
0.45 |
0.55 |
1.35 |
|
|